The HR730 series 80GHz Radar Level Meter refers to the products which work at a frequency modulated continuous wave (FMCW) of 76-81GHz and support four-wire and two-wire applications. There are multiple models of this series, with a blind zone up to 8cm and a range up to 120m. Based on self-developed CMOS millimeter wave RF chips,the products can achieve a more compact RF architecture, higher signal-to-noise ratio, and smaller blind zones. Fearless of the attenuation of radar echoes by steam and dust; Stable measurements can still be achieved for materials with weak reflection characteristics or low dielectric constants.
HighReach self-developed CMOS millimeter wave RF chips achieve a more compact RF architecture;
The 5GHz working bandwidth enables the product to have higher measurement resolution and accuracy;
The minimum antenna beam angle is 3°, and the interference in the installation environment has a smaller impact on the instrument;
Shorter wavelength, better reflection characteristics on solid surfaces, greatly reducing dependence on universal flanges;
Support remote debugging and upgrading, which can reduce waiting time and improve work efficiency;
Support Bluetooth debugging for mobile phones, making it easy for on-site personnel to maintain.
Main Performance Specification | |
Transmission frequency | 76GHz~81GHz |
Measurement Range | 10m;20m;30m;60m;120m |
Measurement Accuracy | ±1mm |
Measurement Interval | Max speed 100ms |
Beam Angle | 3°/8°/20° |
Dielectric Constant Range Used | ≥2 |
Power Supply Range | 12~28.0V DC |
Communication method | MODBUS;HART |
Signal Output | 4~20mA or RS-485 |
Fault Output | 3.8mA,4mA,20mA,21mA,Maintain |
On-site operation/programming | 128×64 Dot matrix display screen/4 buttons; Configurable upper computer setting software |
Process temperature/humidity | T0:-40~85℃/humidity≤95%RH;T1:-40~260℃;T2:-40~1000℃; |
Housing material | Aluminum alloy&Stainless steel |
Process Connection Type | Pipe thread/universal flange/anti-corrosion flange/sanitary chuck/quartz isolation flange |
Process pressure | -0.1~2MPa |
Size | φ125*270mm |
Cable Entry | M20*1.5 |
Dimensional structure(Unit:mm)
v> 3° Schematic diagram of the connection structural dimensions of the normal temperature pipe threaded
v> 8° Schematic diagram of the connection structural dimensions of the normal temperature pipe threaded
A | B | C | H | |
DN80 | φ200 | φ160 | 8-φ17 | 18 |
DN100 | φ220 | φ180 | 8-φ17 | 18 |
DN125 | φ250 | φ210 | 8-φ18 | 18 |
DN150 | φ280 | φ240 | 8-φ20 | 20 |
DN200 | φ340 | φ295 | 8-φ20 | 20 |
Note: Schematic diagram of the structural dimensions of the universal flange at room temperature with a minimum DN80 3 ° beam angle
A | B | C | F | H | |
DN80 | φ200 | φ160 | 8-φ17 | Φ138 | 18 |
DN100 | φ220 | φ180 | 8-φ17 | Φ158 | 18 |
DN125 | φ250 | φ210 | 8-φ18 | Φ188 | 18 |
DN150 | φ280 | φ240 | 8-φ20 | Φ212 | 20 |
DN200 | φ340 | φ295 | 8-φ20 | Φ268 | 20 |
3°Schematic diagram of structural dimensions of beam angle high-temperature (-40... 260 ℃) anti-corrosion flange
The HR3051-DP differential pressure tran···...
HRTU8101 GPRS/GSM Micro-power Measuremen···...
HR8833 is a three-parameter (water level···...
The intelligent digital indicator is con···...
HR8066/67 high-precision static force le···...
HR8003 water level transmitter is one ki···...