The radar level transmitter antenna emits and narrows the microwave pulse. This pulse propagates in space at the speed of light. When it encounters the surface of the measured medium part of its energy is reflected back and received by the same antenna. The time interval between the transmitted pulse and the received pulse is proportional to the distance from the antenna to the surface of the measured medium. Due to the extremely high propagation speed of electromagnetic waves the time interval between the transmitted pulse and the received pulse is very small (on the order of nanoseconds). It is difficult to confirm. The 90X series 26G radar level gauge uses a special demodulation technology to accurately identify the transmitted pulse and The time interval of the pulse is received to further calculate the distance of the antenna from the surface of the measured medium.
Measurement range up to 70 meters covering water level measurement of large reservoirs.
Small antenna size easy to install and add dust cover and other antenna protection devices.
Light weight is about 1KG easy to install.
Multiple output circuit interfaces cooperate with the acquisition system.
Small beam angle concentrated energy stronger anti-interference ability greatly improving measurement accuracy and reliability
Using pulse working mode the radar level gauge has very low transmission power and no harm to human body and environment.
Specification
Housing Seal between the outer casing and the outer cover Silicone Rubber Shell window Polycarbonate Ground terminal stainless steel |
Supply voltage Four-wire system Standard type (6~26) V DC Power consumption max 12mA Allow ripple -<100Hz Uss<lV - (100~100K) Hz Uss<l0mV |
Cable parameter Cable entry/plug M20xl.5 cable entry Terminals Wire cross section 1.0mm² |
Output parameters output signal RS485 communication protocol Modbus Resolution 1. 6u A Fault signal Current output is unchanged;20. 5mA 22mA; 3.9mA duration (0~50)s,adjustable |
Blind zone 天Antenna end |
Max. Measurement distance NYRD-806 30m NYRD-808 70m |
Microwave frequency 26GHz |
Communication Interface /Modbus communication protocol |
Measurement interval About 1 second (depending on parameter settings) |
Adjust the time About 1 second (depending on parameter settings) |
display resolution 1mm |
Working storage and transportation temperature (-40~100) ℃ |
Process temperature (temperature of the antenna section) (-40~250)℃ |
Pressure Max. 4MPa |
Shock tolerance Mechanical vibration l0m/s² (10~150)Hz |
The HR3051-DP differential pressure tran···...
HRTU8101 GPRS/GSM Micro-power Measuremen···...
HR8833 is a three-parameter (water level···...
The intelligent digital indicator is con···...
HR8066/67 high-precision static force le···...
HR8003 water level transmitter is one ki···...